Basic Specification and Main Parameters
Model number
|
JXW45 (DW45)
|
Pole number
|
3P,4P
|
Standard
|
IEC 60947-2
|
Rated working current(In)
|
630A-6300A
|
Rated working voltage(Ue)
|
under AC690V
|
Rated frenquency
|
50/60Hz
|
Short-circuit breaking capacity
|
80KA-120KA
|
Enviroment temeperature
|
-5℃~+40℃
|
Installation level
|
≤2000m
|
Pollution grade
|
Class 3
|
Type
|
Drawer type and fixed type
|
Structure Characteristics of Intelligent Air Circuit Breaker(ACB)
1. Our intelligent air circuit breaker can be of a fixed type and draw-out type. The fixed type air circuit breaker is installed within a special drawer to become a draw-out type breaker. Our circuit breaker consists of a contact system, and arc-extinguishing system, operating mechanism, current transformer, intelligent controller and auxiliary switches, secondary plug and socket, under voltage and shunt releases. The draw-out type air circuit breaker has a holder that is made up of right and left side plates, base, beams, etc.
2. Contact system
It adopts integrated contact system, including the main contact and arc contact.
3. Arc-extinguishing chamber
Each pole has an arc-extinguishing chamber, which works to separate and isolate each electrode. The arc extinguishing chamber is enclosed within the insulating base of the intelligent air circuit breaker, which enforces the mechanical strength of arc extinguishing chamber wall and avoids breakage when it is breaking a large short circuit current.
Environment Conditions for Operation
Temperature condition: -5℃ ~+40℃ ; the average value within 24h not exceed +35℃ .
Elevation: altitude of installation place shall not exceed 2000m.
Atmosphere condition: relative humidity at +40℃ shall not exceed 50%. Higher humidity is permissible at lower temperature condition. When the higher monthly average relative humidity is 90% in the humiddest month , the lowest monthly average temperature of this month is +25℃ . And consider the influence of dew on product surface due to temperature changes.
Pollution grade: gradeIII.
The breaker should be installed according to the requirement on the instruction manual: the vertical inclination degree shall not exceed 5°.
Outline and Installation Dimensions
Product Detail
|
Intelligent universal circuit breaker
Smart switch is durable
|
High contact point
Good electrical conductivity
|
|
|
Thickening steel
Muti-safety protection
High temperature resistance and aging resistance
|
Both MCB and MCCB are electrical line protection devices, but they also have some differences.The difference between a molded case circuit breaker and a miniature circuit breaker is that the electrica
[Circuit breaker knowledge] RCCB manufacturer will introduce the difference between the residual current circuit breaker and the residual current operated circuit breaker.